Pharma clean room factory with sz-pharma.com
Pharma machinery manufacturer in China: Tablet press is mainly used for tablet technology research in pharmaceutical industry. The tablet pressing machine presses powder or granular raw materials into tablets. Its scope of application: Traditional Chinese medicine, western medicine, health products, food, chemical industry, electronics and other industries. The prefabricated container house is a new concept of environmentally friendly and economical house with light steel H-shaped steel and channel steel as the framework, sandwich panel as the wallboard material, space combination with standard modulus series, and bolted or welded components. Discover extra information on tablet punches and dies.
Settling colony count and plankton determination requirements: at the same time of each experiment, count the settling colony of microorganisms in the operating room and laminar flow table, record the results in the user log, and record the original data of the experimental environment in the experiment report. Disinfection requirements: Every week and every operation in the sterile room, the operating table and the dead corners should be wiped with appropriate disinfectant. The specific method is to use sterile gauze impregnation disinfection solution to clean the entire inner surface of the super clean bench, and aseptic room, flow of people, logistics, buffer room floor, transfer window, door handle. Cleaning and disinfection procedures should be from the inside out, from high clean areas to low clean areas. Gradually exit the clean area. Then turn on the aseptic air filter and UV lamp for 1-2h sterilization to kill the remaining microorganisms. At the end of each operation, wipe the workbench with the above disinfection solution, remove indoor moisture, and sterilize with UV lamp for 30min.
Automatic industrial paper folding machine, small desktop origami paper folding machine is suitable for paper folding in various ways. It has a reasonable structure. It uses a large rubber wheel to feed paper. It has accurate separation, stable performance, convenient operation and high efficiency. The minimum folded width is 30mm, which is especially suitable for the folding of the instructions for drugs and cosmetics with small width.Want to konw more, contact SZ pharma, one of the most professional paper folding machine manufacturers & suppliers in China.
Use a Hygrometer: A hygrometer is a device that measures the current humidity level in the room. By regularly monitoring the cleanroom humidity control with a hygrometer, you can identify any fluctuations and take corrective action if necessary. Ventilation: Proper ventilation is crucial for maintaining healthy humidity levels in clean rooms. Ensure that there are sufficient exhaust fans in place to remove excess moisture and carbon dioxide from the air. Additionally, consider installing temperature and humidity sensors to monitor changes in the environment and adjust ventilation accordingly. Control Water Sources: Closely monitor water sources within the clean room, such as sinks or taps, as they can contribute to high humidity levels. Be sure to turn off faucets when not in use and avoid running water unnecessarily.
The clean room workshop is also called the dust free workshop, gmp cleanroom, the industrial clean room (Clean Room) and the dust free room. It refers to the removal of pollutants such as particles, harmful air and bacteria in the air within a certain space, and the indoor temperature,cleanliness, indoor pressure, air velocity and air distribution, noise and vibration, lighting and static control. A specially designed clean room for a particular requirement. That is to say, no matter how the extemal air conditions change, the clean room can maintain the characteristics of cleanliness temperature and humidity and pressure.
For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.
Tablet press dies wholesale factory right now: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.
Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.
Many single-flow type clean rooms are designed as vertical laminar flow, so the uniformity of wind speed is very important. Only uniform vertical laminar flow can effectively eliminate particulate pollution. For non-single-flow type clean rooms, since the concept of particle control is dilution, not immediate elimination, generally speaking, the air exchange rate is far more important than the wind speed, so it is only necessary to measure the air volume. Read more information on sz-pharma.com.